The Batch Burn Incinerator allows waste to be loaded into the primary chamber either manually or with a feeding ram, if so equipped. After the chamber is loaded with waste materials, the burn cycle is initiated.

Once the burn cycle has begun, additional waste loading is inadvisable because exploding cans or bottles may injure the operator.

During the batch burn cycle, waste burns under controlled air conditions for 8 to 12 hours. When the cycle has been completed, the unit shifts to a shut down cycle for final burn out and cool down. After cool down and the removal of ash and non-combustible items, the unit is ready to reload.

Batch Burn Incinerators

Model

Pyromizer

751B

1121B

2151B

3600

5200B

8400B

Unit Volume

Primary Chamber (CU. FT.) 35.3 75 112 215 360 520 840
Secondary Chamber (CU. FT.) 22.1 16.8 27.9 43.2 44.4 73 135

Incinerator Only

Length 6' 3 3/16" 11' 0" 9' 9 3/16" 10' 8 3/16" 15' 5 3/4" 15' 5" 19' 1 1/8"
Width 4' 8 3/8" 4' 11 3/8" 5' 11 3/8" 6' 11 3/8" 6' 10 3/8" 7' 11 3/8" 8' 11 3/8"
Heigth 7' 1 3/8" 9' 1" 8' 8 1/2" 10' 2 1/2' 11' 10 1/2" 13' 6 3/4" 15' 1 1/4"
Stack Heigth (From Incin. Pad) 23' 1 3/8" 27' 11 3/8" 27' 2 3/8" 28' 8 3/8" 31' 10 1/4" 33' 6 1/4" 35' 1 1/4"
Pad Size 8' 6" x 12' 10' x 21' 3" 11' x 20' 11' x 21' 12' x 27' 13' x 26' 6" 14' x 30' 9"
Shipping Weight 8800 14,600 17,800 24,800 40,100 47,650 78,300

Incinerator with Loader

Length         27' 1/4" 30' 1/2" 30' 9 1/2"
Width         6' 10 3/8" 7' 11 3/8" 8' 11 3/8"
Height         11' 10 1/4" 13' 6 1/4" 15' 1 1/4"
Stack Height (From Incin. Pad)   Not Available   31' 10 1/4" 33' 6 1/4" 35' 1 1/4"
Pad Size         12' x 39' 13' x 27' 6" 18' x 42' 9"
Shipping Weight         45,800 53,250 83,700

DO NOT USE FOR CONSTRUCTION. Construction Blueprints will be issued after receipt of order.

Note: All of the above units are designed to be used on a batch burn basis. Waste is loaded into the primary chamber manually. or with a ram feeder is so equipped, until the chamber is full, usually at the end of the day. The burn cycle is then initiated by turning a switch. After burn down the unit goes into a shut down cycle for final burn out and cool down. The following morning the small amount of ash and non-combustible is removed. It is then ready for another load. Opening of the loading of las-pak door on units manually loaded is discouraged during the burn period as exploding aerosol cans or glass bottles may cause injury to the operator.


For more information email simonds-mfg@earthlink.net


Home|Company Information|Pathological Incinerators|Continual Burn Incinerators|The Simonds' Guarantee

  Simonds Manufacturing Corporation
209 Palmetto Street
Auburndale, FL 33823
Phone: (863) 967-8566