The continual burn incinerator (diagram) equipped with an
automatic feed allows for the waste loading at the rated capacity for up to 8 hours. A
system with the automatic ash removal feature increase waste loading at the rated capacity
up to 24 hours on a continual basis.
|
In the Continual Feed process, waste is introduced into a charging
hopper either manually or by an automatic cart dumper. Then the charging hopper door is
closed, the primary chamber refractory-lined gate is raised, and the waste is introduced
into the primary chamber by a hydraulic ram mechanism.
Next, the burning waste is moved through the primary chamber by a charging ram and one
or more ash pushers. They move the steadily-reducing mass of waste to the end of the
chamber. Then, if the system is equipped with automatic ash removal, the ash drops through
a water seal into a water filled tank. From there it is moved by either a drag conveyor,
the Simonds proprietary "Ash Sweep," or the Simonds "Ash Kicker," to a
dumpster for removal from the area. In systems not equipped the automatic ash removal, the
ash remains in the primary chamber until the system is cooled down. It is them removed
manually.
At or near capacity our continuous feed incinerators operate without auxiliary fuel.
Our systems maintain precise control over the combustion process through a design which
rigidly governs the introduction of all air.
|
Continual Burn Incinerators
With and Without Heat Recovery
|
Model
|
#2D
|
#3D
|
#4D
|
#5D
|
#6D
|
#7D
|
Waste Consumption
|
Waste @ 9380 BTU/LB LBS./HR* |
500 |
850 |
1000 |
1500 |
2050 |
3000 |
| Waste @ 8500 BTU/LB LBS./HR* |
600 |
925 |
1250 |
1750 |
2250 |
3250 |
| Waste @ 6500 BTU/LB LBS./HR* |
650 |
1000 |
1500 |
2000 |
2850 |
4000 |
Volume
|
ALL Primary Chamber (CU. FT.) |
150 |
267 |
412 |
539 |
693 |
956 |
| 1 sec* Secondary Chamber (CU. FT.) |
104 |
184 |
241 |
311 |
409 |
615 |
| 2 sec* Secondary Chamber (CU. FT.) |
177 |
334 |
412 |
622 |
821 |
1141 |
Incinerator w/ Heat Feeder
and Ash Removal |
Stack Height |
35' 6" |
36' 1" |
37' 1" |
37' 7" |
43' 7" |
40' 1" |
| Pad Size With Heat Recovery |
38' x 42' |
43' x 45' |
46' x 50' |
49' x 58' |
49' x 68' |
61' x 69' |
| Pad Size W/O Heat Recovery |
18' x 32' 6" |
19' x 38' |
20' x 40' 6" |
20' x 45' 6" |
21' x 47' 6" |
23' x 49' |
| Shipping Weight W/ Heat Recovery |
86,000 |
107,000 |
127,000 |
177,000 |
202,000 |
282,000 |
| Shipping Weight W/O Heat Recovery |
71,000 |
86,000 |
101,000 |
138,000 |
154,000 |
210,000 |
| Steam Output LBS. per Hour** |
2200 |
3500 |
4300 |
6600 |
8200 |
11,500 |
| |
Standard Feeder |
Model A |
Model BB |
Model B |
Model B |
Model B |
Model B |
DO NOT USE FOR CONSTRUCTION. Construction Blueprints will be issued
after receipt of order.
NOTE:The Continual burn procedure permits waste to be loaded periodically at
the rated capacity for a period of up to 8 hours. If system is equipped with automatic ash
removal, waste can be loaded and burned up to 24 hours per day.
* Up to 7.5% of total can be Type IV waste
**Under theoretically optimum conditions 120 PSIG: feedwater from and at 212 degrees F
Home|Company Information|Batch
Burn Incinerators|Pathological Incinerators|The
Simonds' Guarantee
| |
Simonds Manufacturing Corporation
209 Palmetto Street
Auburndale, FL 33823
Phone: (863) 967-8566
Fax: (863) 967-8538 |
|